Вопросы и ответы
What is the difference between 05-16250 and 05-16251? Do I need both, and under what circumstances? It looks like it is just all one piece.

05-16250 can be used with cable housing O.D. of 1/4" thru 7/32". If the housing O.D. is 3/16", spacer part number 05-16251 will be required to grip the housing.

Regarding the Cable Safe: Can this be used with cable A-930 or any of the cables that comes with the ends installed?

The A930 or any cable with swaged threaded ends can not be used with the 05-16250 cable safe. Only cables with 1/4" O.D. outer housing, and a solid wire end can be used. A930, and other swaged threaded ends, will need to use part number 05-16252, which has two halves. The 05-16250 is a one piece unit and swaged ends will not allow it to be installed.

What size hole for the cable safe 05-16250?

7/32 or 1/4" cable housing.

What is the diameter of the hole to drill for bolting to the firewall?

You will need to drill a 9/16" hole.

What is the maximum firewall thickness? Composite planes use 1/4 plywood and then stainless steel sheet.

This will have a max panel thickness of .375".