GENERATOR CONTROL UNIT 14 VOLT 35 AMP FAA PMA REPLACEMENT
94 200
₽
Арт.
07-00618
Описание
14V, 35A Generator Controller Unit: Delco Remy Type A Generator System Voltage Regulator G1350N 14V 35A Delco Remy Generator Voltage Regulator PMA Replacement.
What’s included:- Installation Drawing
- Warranty Card
- Product Eligibility Catalog (PEC)
- Troubleshooting Notes
- Instructions For Continued Airworthiness Maintenance (ICA)
- The Voltage Regulator (VR) controls the Generator’s field to keep the
aircraft electrical system voltage at a specific level. This controller has a
“Type A” regulator which excites the field of the alternator by providing
controlled ground to one side of the field (F), with the other side internally
connected to the armature.
- The Generator Build-up function allows the rotating generator to build-up its
output from a low residual voltage to the system’s voltage regulation point.
G1350N 14V 35A Delco Remy Generator Voltage Regulator PMA Replacement
Electronics Field Controller/Switching- The VR electronics switch turns the field current on/off so fast (several
times a second) that the output voltage of the generator stays at the VR set
point. When the generator’s output voltage exceeds the VR set point, the switch
opens, current flow stops, and the generator’s output decreases.
- The Current Limiter (CL) controls the maximum output current the generator
can produce. It turn off the field excitation when the output current exceed the
CL set point (determined by the generator’s current rating). It allows normal
field excitation when the generator output is below the GCU CL set point.
- The Reverse Current (RC) Protection circuit blocks the battery current from
going back to the generator. It allows current to flow only from the generator
to the battery and system.
- The GCU’s design will cause the field current path (between the field and
ground) to open if the field control device becomes internally ground shorted.
This means that the GCU will not induce Over-Voltage (OV) problem into the
system. The GCU does not protect the system against externally induced OV
faults.
- The on-unit system Trouble-Shooting Lights, TSL, identify how the system is
operating and, helps with system testing and troubleshooting. The lights
indicate Generator Off/On-line (GO, GREEN), Voltage Regulation (VR, GREEN),
Current Limit (CL, RED), and Parallel (EQ, or Load sharing, GREEN).
- Footprint Compatible to Delco-Remy’s VR
- Increase Regulator Life
- Not Temperature Sensitive
- Prevents Regulator cycling at low RPM
- Eliminate Regulator Noise
- More Precise Current Limit
- Prevents Battery Current Flowing to the Generator
- GCU will not cause OV fault in the system
Features
Eligibility
- OEM PN(Delco-Remy): 1118704, 1119220, 1118892, 1118704
- OEM PN(Electrodelta): VR300-14-35
- OEM PN(Cessna): 0413205-6, 0413205-8, 0413205-10
- OEM PN (Beech): 35-380142-7
- OEM PN (Piper): 450-390
- OEM PM (Mooney): M20, M20A, M20B
- Approved Aircraft CESSNA: 150, 150A, 150B, 150C, 150D, 150E, 150F, 150G, 150H, 172, 172A, 172B, 172C, 172D, 172E, 172F, 172G, 172H, 175, 175A, 175B, 175C - LAKE: LA-4 - BEECH: 23, 35-B33, 35-C33, 35-E33, 35-F33 - PIPER: PA-24-180, PA-24-250; PA-18, PA-18A, PA-18S, PA18-105, PA18S-105, PA18-125, PA18AS-105, PA18S-125, PA18-135, PA18A-135, PA18AS-135, PA18S-135, PA18-150, PA18A-150, PA18AS-150, PA18S-150
Отзывы Оставить отзыв
Вопросы и ответы
Вопросы отсутствуют.