ROCHESTER 3080-37 OIL TEMP PROBE 5/8-18 NF3 100-250F

38 955
Арт.
3080-37
Описание

Electrical sender (Probe) 3080-37 for cluster-type instrument.

5/8"-18, 10/32 Thread
Resistance (Ohms)
Note: Used 177-18 Thermistor curve “E”

    100°F =497Ω
    150°F =179Ω
    200°F =72Ω
    250°F =34Ω

Отзывы Оставить отзыв

Отзывы ещё не добавлены

Вопросы и ответы
What is the resistance (ohms) of the probe?

Ohms vary by temperature. Please see the "Specifications" tab on this web page for the Ohms breakdown by temperature.

Does the Rochester 3080-37 oil temp probe come with the washer, nut and gasket?

The Rochester 3080-37 oil temp probe does come with the washer, nut and gasket.

Does this probe operate on 12 and 24 volt systems?

Power is not connected to the Rochester oil temperature probe (3080-37) and therefore the voltage of your system is not a factor.

Is this Rochester 3080-37 oil temp probe FAA/PMA approved and does it replace P/N S2335-1?

This unit does not come with FAA/PMA approval, but is the same make and model, and used for the same engine applications in experimental aircraft.

Can this 3080-37 replace the S2334-4?

Per the manufacturer, there is no cross reference of this part to S2334-4, only to Cessna S32335-1.

Will this unit work with my Dynon D180?

Dynon recommends using Dynon probes with their EFIS systems.

What is the 3080-37 probes length?

Approx 1/2 inch.

Should the threaded end rotate?

Yes, the threaded end rotates on part # 3080-37.