MGL TYPE K- THERMOCOUPLE EXTERIOR CABLE

15 825
Арт.
11-16831
Описание

Since Bayonet CHTs are made with short length leads, extending them is often necessary. CHTs and EGTs should be extended with type-K extension wire directly to the RDAC, or if the RDAC is mounted outside the engine compartment (or if you are connecting directly to a Single instrument) then type-K extension should be used at least until the sender lead exits the engine compartment (where temps are high).

The CHT/EGT extension kit includes type-K thermocouple wire. Splice barrels and a length of meltable-inner heat shrink tubing will be required for installation, Raychem SCL-3/16 heat shrink is recommended per manufacturer.. This heat shrink gets quite soft inside when it is heated up which eliminates all air inside the splice and makes an airtight seal.

Отзывы Оставить отзыв

Отзывы ещё не добавлены

Вопросы и ответы
Would this be appropriate to extend egt and cht wires inside the cowling? Going to firewall mounted RDAC

Yes, but please be aware that this is for experimental applications only.